top of page
Never MT Natural Gas Pressure Boosters for scientific glassblowers

Torch Boosters elevate utility natural gas for direct supply to torches and burners

Natural Gas Cylinders hold high volumes of gas at only 275 psi

Purchase a G-TEC Natural Gas Pressure Booster 

How To Install your G-TEC System

Contact G-TEC if you have questions

When your application needs high gas flow volumes for short periods of time a Never M-T Natural Gas Pressure Booster System is the solution!

Some torch applications don't use a lot of gas most of the time, but sometimes need a lot of gas for a short time. A Torch Booster that supplies high gas flow all the time is too expensive and can incur a lot of wear and tear without doing much work...a Never M-T System supplies the right gas flow volume at any time!

Single cylinder natural gas Never MT Pressure Booster for scientific glassblowers

How does a Never M-T Natural Gas Pressure Booster System work?

G-TEC Never M-T Systems use a Refueler and Adsorbed Natural Gas Cylinder to economically supply all the gas your torch needs, whether a lot or a little.

The Refueler system connects to a standard low-pressure utility gas pipe and fills one or more cylinders to 275 psi then shuts itself off. The cylinders use a regulator to reduce pressure from 275 psi to whatever pressure your application requires. When you light your torch gas flows from the cylinder(s) and as you work the gas level in the cylinders falls. At either 170 psi (Refueler 60) or 225 psi (Refueler 180) the Refueler turns itself back on, refills the cylinders to 275 psi, then turn itself off again.

Once started the process is fully automatic and will repeat over and over as long as the Refueler is not turned off - it is like having a cylinder that never runs out of gas.

When is a Never M-T Natural Gas Pressure Booster System a better choice instead of a Torch Booster?

Torch Boosters are designed for applications like cutting plate steel, thermal spray and brazing where the gas flow volume requirement is steady all day, the torches use gas at about the same rate hour after hour. Since Torch Boosters do not store any gas they run all the time and must be sized for the highest gas flow volume an application might use.

Other applications run in cycles and the gas flow volume requirement can vary during the cycle. Thermal deburring and removing flashings from injection molded parts go through a number of steps and gas may only be used for a few seconds during a 2 minute cycle. Other applications like scientific glassblowing normally use gas at low flow volumes most of the time but sometimes need high flow volumes for a few minutes.

In these applications a Torch Booster would be running all the time even though gas is used only a small part of the time. You would need a larger, more expensive, Torch Booster to meet a high flow requirement that occurs less than 10% of the time.

A Never M-T System balances cost and performance because it can meet the demand for high flow gas when needed but the compressor only runs when the cylinders are being refilled. In addition to putting less wear and tear on the compressor a Never M-T System is often much less expensive than the Torch Booster that would be required to supply peak gas flow volumes.

A Single Cylinder Never M-T System combines a G-TEC Refueler 60, NG-130 Adsorbed Natural Gas Cylinder, Regulator and Simple Tee to supply natural gas ins a high performance economical system.

How does the Single Cylinder Never M-T Refueler System work?

The Refueler 60 fills the NG-130 Adsorbed Natural Gas Cylinder up to 275 psi then turns itself off when the cylinder is full.

When your torch is lit gas is drawn from the cylinder until pressure falls to 170 psi then the Refueler 60 turns itself back on, refills the cylinder, then again shuts off.

The cycle will repeat over and over as long as the Refueler 60 is not turned off. Average gas flow capacity is 60 cf/hr and the NG-130 Cylinder holds 130 cubic feet of gas for peak demand periods.

Natural gas pressure boossters are installed indoors where natural gas is used

A Multi-Cylinder Never M-T System combines a G-TEC Refueler 180, up to 4 NG-130 Adsorbed Natural Gas Cylinders, regulator and a 4 cylinder Continuous Operation Manifold to supply natural gas in a high performance economical system.

How does the Multi-Cylinder Never M-T Refueler System work?

The Refueler 180 fills the NG-130 Adsorbed Natural Gas Cylinders to 275 psi then turns itself off when the cylinders are full. When torches are lit gas is drawn from the cylinders until pressure falls to 225 psi then the Refueler 180 turns itself back on, refills the cylinders and again shuts off.

 

The cycle will repeat over and over as long as the Refueler 180 is not turned off. Average flow capacity is 180 cf/hr and each NG-130 cylinder holds 130 cubic feet of gas - with 4 cylinders total capacity is 520 cf. The system con be configured with 2, 3 or 4 cylinders.

Multi cylinder natural gas Never MT Natural Gas Pressure Boosters for large scientific glassblowing shops
Never M-T Refueler Systems copy.jpg

Torch Boosters elevate utility natural gas for direct supply to torches and burners

Natural Gas Cylinders hold high volumes of gas at only 275 psi

Natural Gas Pressure Booster Systems are installed indoors

Purchase a G-TEC Natural Gas Pressure Booster 

How To Install your G-TEC System

Contact G-TEC if you have questions

G-TEC manufactures compact natural gas compressors.
bottom of page